An Assessimus Group Company
All products made in the USA

9554-(   )

Variable Frequency Modules

Model 9554-( ) Variable Frequency Modules for use with Model 9354-1 or 9354-2 Transient Generator as specified by Test Method CS-116, MIL-STD-461D/E/F/G

Description

APPLICATION

Utilizing the high voltage power source in the Solar Model 9354-1 or Solar Model 9354-2 Transient Generator, five individual modules can be connected to provide tuning of damped sinusoidal waves from 10 kHz to 100 MHz.

DESCRIPTION

Individual modules enable tuning of damped sinusoidal waves in accordance with the requirement of Method CS-116, MIL-STD-461D/E/F/G The part number of each module indicates the frequency range of the module. For example, P/N Solar Type 9554-10k/100k indicates a range of 10 kHz to 100 kHz. The five modules are identified as:

Solar Type 9554-10k/100k variable frequency module

Solar Type 9554-100k/1M variable frequency module

Solar Type 9554-1M/6M variable frequency module

Solar Type 9554-6M/50M variable frequency module

Solar Type 9554-50M/100M variable frequency module

Two cables connect the module to the Model 9354-1 or Model 9354-2. One cable is a single insulated wire to carry high voltage DC to the module. The other cable delivers low voltage DC to the module for operation of relays.

OPERATION
The frequency of the damped sinusoidal wave is adjusted by a tuning control on the panel of the module. A graph showing frequency versus turns count on the tuning control is supplied.

With the selected module connected, the charge voltage of the module is adjusted by the AMPLITUDE control on the Model 9354-1 or Model 9354-2 Transient Generator. The
AMPLITUDE knob is marked in percentage of the available charge voltage for the module being used.

The amplitude and frequency of the damped sinusoidal wave into the load can be determined by an associated oscilloscope with a 50 Ω input.

After the charge voltage is adjusted to the desired value, the damped sinusoidal wave is applied to the load by pushing the button on the module.

Specifications

Dimensions: 10″ wide x 5″ high x 12″ deep (25 cm x 12.7 cm x 30.48cm)

Weight: 10-12 pounds (4.5-5.5 kg)*

* Varies with model

Useful Accessories

Solar Type 9125-1 Calibration Jig

Solar Type 9142-1N Injection Probe

Solar Type 2925-1 Calibration Jig

Solar Type 9335-2 Multiple Impedance Coupling Device

Solar Type 9410-1 High Voltage Attenuator
The input to the Type 9410-1 can be used for a 50 Ω coaxial load

Solar Type 9841-1 1000 V Termination
50 Ω coaxial 1 W average power. Typical input VSWR in a 50 Ω system under 1.5 from DC to 1 GHz.

Need a custom configuration?

Send your specifications and our engineers will quote a solution.