Description
|
Effective March 2, 2017 In response to the changes in MIL-STD-1399-300B, we have incorporated an independent 60 Hz sync input function. This is accomplished through the addition of a selector switch position and associated internal wiring. The discharge switch has also been updated to a solid-state type switch. Due to these changes, we have rolled the part number of the generator from 7399-2 to 7399-3. APPLICATION
A SYNC TEST function is provided for adjusting the trigger circuit of the associated oscilloscope for response to a single pulse. After this adjustment of the scope, it is ready for viewing the spike. When the READY lamp indicates the storage circuit has been charged to the selected peak voltage, the pushbutton is depressed which triggers the sync circuit of the oscilloscope. All connections to the Solar Model 7399-3 are isolated from the chassis. The chassis is grounded through the third wire in the power cord in accordance with safety regulations. |
||||||||
Specifications
Peak amplitude: No load 100-2500 V100-2000 V 0.5 Ω load
Duration: No load to 50% of peak 0.5 Ω load ≈50 µS≈31 µS
Duration to zero: No load crossover ≈100 µS 0.5 Ω load ≈77 µS
Repetition rate: 2 pulses per minute
Phase adjustment: Spike position adjustable from 0 to 360 on 50, 60 or 400 Hz sine wave
Internal impedance: Less than 0.1 Ω
Peak output power: 8 MW into 0.5 Ω load
Power current in series injection mode: Handles up to 100 A of current at power frequencies
Power requirements: 115 V 60 Hz, 2.0 A
Dimensions: 12.56″ wide x 21.06″ high x 15.50″ deep (31.9 cm x 53.5 cm x 39.4 cm)
Weight: 90 pounds plus 5 pounds for accessories (43.09 kg)
Total shipping weight: 120 pounds (54.4 kg)
Figures
Components (Supplied)
Solar Type 739945 Plug-in Unit
For series injection of spike into power lines
Solar Type 739950 Plug-in Unit
For parallel injection (using external components)
Mating connectors
Two 100 A styles, for power connections; two 50 A styles, for external resistor
Useful Accessories (Not Included)
Type 6220-1B Transformer
Can be used as a high current series inductor
Type 7032-1 Isolation Transformer
For removing power ground from the case of the scope (see Figure 23, MIL-STD-1399-300B)